Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04CM00341
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/27/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) CORRECTION MADE OK OK FOR CONCRETE | |
04/26/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) WORK COVERED WITHOUT RE-INSPECTION 2) MIKE-DO NOT POUR CONCRETE UNTIL YOU EXPOSE DBL FIXTURE FITTING FOR BACK TO BACK FLOOR DRAINS, AND HAVE IT INSPECTED |
|
04/25/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY FOR INSPECTION | |
04/22/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) AS WE DISUSSED, A DBL WYE WITH AN EIGHTH BEND PUTS THE POINT OF VENT BELOW THE TRAP WEIR ON ALL FIXTURES EXCEPT WATER CLOSET. USE 3" DBL FIXTURE FITTING AT P-11'S 2) OK TO COVER THE REST |