Permit: T04CM00296

Parcel: 129133180


Addresses:

901 E 35TH ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
07/29/2004 BUILDING - FINAL Approved IVRS - Inspection :*
07/21/2004 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) POST ADDRESS ON 35 TH ST. SIDE OF HOUSE 2) OUTSIDE HOSE BIB REQUIRES ANTI-SIPHON VALVE 3) OUTLET FOR DISH WASHER MUST BE READILY ACCESSIBLE 4) INSTALL RANGE GAS VALVE AND CAP 5) CAULK TUB AND TOILET 6) BATHROOM GFCI HOT WHEN TRIPPED 7) BEDROOM WINDOW SECURITY BARS MSUT BE READILY REMOVABLE 8) SMOKE DETECTOR IN BEDROOM INOPERABLE 9) LABEL ALLL CIRCUITS IN ELECTRIC PANEL 10) DIELECTRIC GREASE REQUIRED ON ELECTRIC ALUMINUM
07/19/2004 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
06/03/2004 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*