Permit: T04CM00287

Parcel: 11904600F


Addresses:

3743 S 12TH AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04CM00287

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/31/2004 PLUMBING - FINAL Approved OK FOR C OF O
03/30/2004 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) PVC SCH 40 IS NOT APPROVED WITHIN STRUCTURE AT BACKFLOW PREVENTORS. 2) MUST PROVIDE VACUUM BREAKER AT HOSE BIB. 3) MUST COVER VENT FOR GREASE TRAP. 4) MUST PROVIDE BACKFLOW PREVENTION FOR EACH CARBONATED WATER.
03/29/2004 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ TRAP MUST BE THE SAME SIZE AS THE DRAIN IT SERVES. SEE SECTION 1003.3 94 UPC.
03/26/2004 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) TRAP SEAL CANNOT BE MORE THAN 4" OR LESS THAN 2" SEE SECTION 1005.0 94 UPC.
03/23/2004 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) MUST USE A APPROVED STRAP FOR INDIRECT WASTE FOR PEEP SINK 2) MUST USE A DIRECTIONAL FITTING IN LIEU OF SAN-TEE FOR TRIPLE COMPT. SINK SEE 405.494' UPC 3) MUST CAULK ALL FIXTURES 4) MUST PERM MARK OR STICKER FOR ANZUL VALVE LOCATION PRIOR TO FINAL INSPECTION 5) SOIL WATER TEST IS OK