Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM00278

Parcel: 140324330

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM00278

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/23/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/15/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*
03/12/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ROOF NOT COMPLETELY NAILED 2) COMPLY WITH SHEAR TRANSFER NAILING 3) HOLDOWN SOUTHWEST CORNER NOT INSTALLED PER PLAN 4) REAR GABLE TRUSS NOT RESTING ON DBL TOP PLATE 5) KNEE WALL MISSING PLATE
03/11/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ WILL CHECK EPOXY HOLD DOWN AT INTERMEDIATES SOUTHWEST WALL.