Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM00278
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/23/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
03/15/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000* | |
03/12/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) ROOF NOT COMPLETELY NAILED 2) COMPLY WITH SHEAR TRANSFER NAILING 3) HOLDOWN SOUTHWEST CORNER NOT INSTALLED PER PLAN 4) REAR GABLE TRUSS NOT RESTING ON DBL TOP PLATE 5) KNEE WALL MISSING PLATE | |
03/11/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ WILL CHECK EPOXY HOLD DOWN AT INTERMEDIATES SOUTHWEST WALL. |