Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/04/2005 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 09/13/2004 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/NO CORRECTIONS MADE! CONTRACTOR NEEDS TO MAKE CORRECTIONS AS NOTED ON MAY 25, 04. I WILL CALL AND ADVISE |
|
| 05/25/2004 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) CONDENSER INCORRECT FUSE SIZE - EXCEEDS MAX ALLOWABLE. 2) FURNACE, WTR HTR FLUES UP THRU ROOF - USE B-1 VENT WITH PROPER TERMINATION ON ROOF. 3) WHAT IS OPENING THRU MASONRY WALL REAR OF FIRNACE ROOM INTO HOUSE? RETURN AIR? DOES IT NEED TO BE BLOCKED? OR CONNECTED? 4) CONDENSATE IMPROPER DRAIN LINE. INCREASE TO 3/4" PVC COPPER AND TERMINATE TO SOIL. DON'T DUMP ON CONCRETE DRIVEWAY, OR SIDEWALK. |