Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/23/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/02/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NEED PAPERWORK ON BROKEN TRUSS REPAIR 2) BANG PLATES AT KITCHEN TOP PLATE 3) LOOSE T & P LINE AT TUB 4) FINISH FRAMING AT SHOWER PAN 5) 12" TO LIGHT CAN ABOVE SHOWER 12" TO PEX 6) HOLE IN REAR HOSE BIB LINE 7) ONE DAMAGED GUSSETT 8) POTABLE WATER NEED PRESSURE TEST (GAUGE) |