Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2004 | FRAMING | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/29/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SAME AS LAST INSPECTION |
|
| 04/14/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000* | |
| 04/13/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT WATER HEATER FLUE 2) NO TEST ON DWV'S 3) SEE AT FROM 4/9/04 INSPECTION 4) WATER LINES OK | |
| 04/09/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) PROVIDE ENGINEER REPAIR FOR TRUSS A13, A16A 2) SERVICE WIRE NOT MADE UP 3) ROMEX NOT ALLOWED TO BE STAPLED ON IT'S SIDE 4) MOVE ELECTRICAL WIRES AWAY FROM GUSSETT PLATES 5) NO RISER INSTALLED 6) NO TEST ON DWV'S 6) NAIL PORTECT ELECTRIC WITHIN 1 1/4 FROM EDGE OF STUD 7) STOPPED INSPECTION, HAVE TRADES WALK HOUSE BEFORE RECALL. TO MANU ITEMS |