Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM00187

Parcel: 12613018A


Addresses:

4540 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T04CM00187

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/26/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*/ CORRECTIONS MADE REVISED CITY APPROVED PLANS ON SITE.
03/22/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) WATER PIPING INSTALLED PER PLAN 60 PSI TEST OK. WASTE AND VENT THRU ROOF ALREADY APPROVED 2) 20 PSI PRESSURE TEST FROM METER TO (1) ROOF TOP UNIT, (1) WATER HEATER, (2) WOKS, (1) 2 BURNER STOVE TOP AND (1) GRIDDLE PARTIAL APPROVAL PENDING CITY APPROVED DRAWING SHOWING ACTUAL INSTALLATION
03/12/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ 1) FINISH WORK ON INTERMEDIATE AND CALL IN. 2) INSTALL GAS PIPING PER PLAN OR HAVE CITY APPROVED DRAWING SHOWING INSTALLATION.