Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04CM00187
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/26/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* | |
03/25/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ PARTIAL APPROVAL PENDING STAMPED LETTER FROM MECH ENGINEER DELETING SAMPLE BOX AT INTERCEPTOR. | |
03/23/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) PROVIDE PERM CAP (GLUE) NOT JIM CAP ON ABANDONED VENT FOR GREASE WASTE. FILL VENT WITH WTR HTR FOR TEST. 2) PROVIDE CITY APPROVED PLANS AT TIME OF INSP AND SUPPLY ACCESS TO BLDG. (10:20 AM) 3) PROVIDE C.O. ON GREASE TRAP VENT. | |
03/01/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000* | |
02/27/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | 1) WATER TEST THRU ROOF ON WASTE AND VENT APPROVED PENDING REVISED DRAWING SHOWING RED LINES FROM PLAN DATED 2/26/04 PIMA COUNTY | |
02/26/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) PROVIDE CITY APPROVED DRAWING SHOWING ACTURAL INSTALLATION. PROVIDE REVISED DRAWING SHOWING INSTALLATION OF VENT FOR GREASE TRAP AND ORIIENTATION OF GREASE TRAP 2) PROVIDE FULL SIZE UPPER TERMINAL CLEANOUTS AT 4" AND 3" BRANCHES 3) PROVIDE 3" DRAIN CLEAN OUT FOR P-12 AND P-3 WET VENTED SECTION 4) WATER TEST UNDER SLAB THRU ROOF PARTIAL ON WASTE AND VENT PENDING CORRECTIONS, CITY APPROVED DRAWING AND RETEST FOR CONDITIONS ABOVE 5) NEED TO SEE 6 LOCATIONS OF PERM CAPS ON SEWER 6) PROPER SUPPORTS NEEDED ON HORIZONTAL VENT PIPING |