Permit: T04CM00139

Parcel: 108163550

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/19/2004 FRAMING Approved IVRS - Inspection 0000*
04/15/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) SHIM GARAGE GLUE LAM POSTS-2 ON N. WALL AND 1 AT DINING ROOM 2) NAIL N.W. GARAGE HIP TRUSS 3) TIGHTEN LOOSE H.D.'S AND ADD NUT 4) NEED FIREBLOCK N. OF STOVE VENT 5) STRAP TOP PLATES AT FRONT BAY 6) SHIM STRINGERS AT PLATFORM AND HEADER 7) MOVE ROOFING OFF FURNACE FLUE 8) SEAL FASCIA/FOAM OVER FRONT DOOR