Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM00128
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/11/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
03/04/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) OVERSPAN GARAGE WALL AT FRONT ENTRY 2) ROOF TO WET TO WALK (RAINING) 3) OVERSPANS FRONT OF HOUSE 4) BATHROOM WALL WEST SIDE-NOT COMPLETELY FRAMED 5) SHIM 3 POINT BEARING TRUSSES 6) CHECK ENTIRE HOUSE FOR OVERSPANS | |
03/02/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) PROVIDE BLOCK UNDER PONY WALLS PER PLAN 2) GABLE END BRACING NOT PER PLAN 3) SHEAR TRANSFER AT ENTRY NOT PER PLAN 5/SD3 SEE 16/SD3 FOR ENTRY REQUIRES P-1 SHEAR 4) NAIL PERIMETER BLOCKS |