Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T04CM00106
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/12/2004 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :*/ 1) REMOVE WATER HEATER VENT IF NOT USING 2) OK TO SHEETROCK | |
| 07/07/2004 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) VENT PIPES-1" MINIMUM CLEARANCE TO COMBUSTIBLE 2) INSULATE ALL EXPOSED SHEET METAL FITTINGS 3) ISOLATE ALL REFRIG. COPPER FROM STEEL/WATER FITTINGS |