Permit: T04CM00106

Parcel: 136192040

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T04CM00106

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
07/22/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*/ 1) WATER TEST THRU ROOF WASTE AND VENT OK 2) H20 TEST ON H20 PIPING OK
07/22/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :I AM UNABLE TO MAKE THIS INSP AT 1:30PM DUE TO HEAVY WORKLOAD PLEASE RECALL
07/16/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) WATER TEST THRU ROOF ON WASTE AND VENT IS REQUIRED 2) SEE INSPECTION DATED 7/12/04 FOR OTHER COMMENTS 3) DRAINAGE FOR LAV TO BE 1 1/2" FROM BARREL OF FITTING TO FIXTURE NOT TO EXCEED 42"
07/12/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) INSTALL PER APPROVED PLAN ON H20 PIPING AND WASTE AND VENT OR PROVIDE CITY APPROVED REVISED PLAN ON SITE OF YOUR INSTALLATION 2) ALL PIPING TO BE SUPPORTED WITH APPROVED METHODS AND MATERIALS 3) H20 PIPING TO HAVE HOT AND COLD SEPERATION PER INSTALLATION INSTRUCTIONS 4) PROVIDE PRESSURE TEST ON H20 PIPING WITH GAUGE
07/09/2004 PLUMBING - INTERMEDIATE Cancelled IVRS - Ri canceled