Permit: T04CM00092

Parcel: 140106540

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/28/2004 FRAMING Approved IVRS - Inspection :
See detailed listing on site.| 999*
04/26/2004 FRAMING Partial Approval IVRS - Inspection :
See detailed listing on site.| 999*/ 1) FIREBLOCK KITCHEN ENTIRE AREA COMMON TO FLOOR JOIST SPACE ENTIRE LENGTH OF GLU 2) DWV TEST TO GO THROUGH ROOF
04/22/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) FIRE STOP ALL AREAS OF CONCERN (KITCHEN AREA AT CEILING) 2) INSTALL 10D NAILS HANGERS 3) STRAP ALL ELECTRIC PENETRATIONS THROUGH FRAMING 4) SECURE ELECTRIC AWAY FROM SHARP OBJECTS 5) STRAP ALL PLUMBING 6) REMOVE ALL INSULATION 7) ITEMS NOT CORRECTED 7) STOPPED INSPECTION COMPLETE ALL AND RECALL
04/13/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) NO PLANS 2) FIREBLOCK ? KITCHEN AREA ( PASS THROUGH AT CEILINGS) NAIL PROTECT PLB AND ELECTRIC 3) REMOVE INSULATION THROUGHOUT 4) STOPPED INSPECTION 5) REFEE DUE
04/12/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) WIRE ROMEX INTO EXHAUST FANS 2) INSTALL BANG PLATES ELECTRIC AND PLUMBING THROUGHOUT 3) USE 10D NAILS ALL HANGERS 4) REMOVE INSULATION GARAGE CEILING 5) GARAGE OSB SHEARWALL TO CARRY TO UNDERSIDE OF FLOOR JOISTS 5) FIRE STOP KITCHEN CEILING 6) DWV TEST TO GO THROUGH ROOF 7) INSTALL DOUBLE STUDS ON GIRDER TRUSSES 8) FIRE BLOCKS MISSING GARAGE WALL TO HOUSE 9) INSTALL POSITIVE CONNECTION ALL TRUSSES AT BEARING POINTS 10) STOPPED INSPECTION
04/07/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) REMOVE ALL INSULATION 2) COMPLETE LATH 3) STOPPED INSPECTION