Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :*/ 1) CORRECTIONS MADE OK 2) OK TO COVER ALL AREAS 3) CONTRACTOR TO INSURE SS SCREWS ON CLOSET FLANGE | |
05/20/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) ALL HORIZONTAL X HORIZONTAL DRAIN LINES INCLUDING TRAP ARMS REQUIRE SWEEPS. 2) UPSTAIRS CLOSET FLANGE TO HAVE STAINLESS STEEL OR BRASS SCREWS - NOT SHEET ROCK SCREWS. REMEMBER, PIPING TO BE SUPPORTED AT END OF BRANCHES, CHANGES IN DIRECTION OR ELEVATION. |