Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/22/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) TESTING FOR BACKFLOW DEVICE COMPLETE 2) FINAL OK S.T.O.I. 3) LAST INSPECTOR ON JOB PLEASE PROVIDE GAS CARD |
| 03/19/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) FRONT AND REAR DOOR LOCKED |
| 03/15/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ LEAK AT WTR FILTER FOR ICE. INDIRECT WASTE FOR ICE NOT TO CODE - RUN INDEPENDANT. ALSO NEED TO SEE AIR GAP OR BACKFLOW DEVICE. ANCHOR EXPANSION TANK. TESTING ON BACKFLOW DEVICE. LABEL ON CEILING FOR LOCATION OF ANSEL VALVE. |