Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/08/2004 |
SHEET ROCK NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 04/07/2004 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) SHEARWALL G-1 MAXIMUM 7" ON CENTER NAILING PATTERN 2) SHEARWALL G-3 4" NAILING USING NAILS NOT SCREWS 3) INSTALL BLOCKING LOWER FLOOR, FLOOR JOISTS AND INSTALL 8 NAILS THROUGH SHEET ROCK INTO BLOCKING SEE DETAIL 2/SD2 |
| 04/06/2004 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) CANNOT USE SCREWS IN SHEAR WALLS |
| 04/05/2004 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) SHEAR WALL G-3 KITCHEN 4" NAILING 2) SHEAR WALL G-1 MAINTAIN 7" NAILING |