Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/26/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/20/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :STRAP PORCH BEAMS AT BEARING NEED POSITIVE CONNECTION LEDGER TO BEARING BEHIND NEED ALSO POSITIVE CONNECTION (LAG BOLTS OR EQUIV) PORCH LEDGER TO EXISTIN ON WEST END OF PORCH STOPPED INSP |
|
| 07/13/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :*/ 1) PARTIAL CLIP A35'S LEDGER TO STUDS OK ITO COVER EXTERIOR 2) WILL NEED TO INSTALL A35'S PORCH LEDGERS TO 2 X 12 RAFTERS 3) WILL NEED TO INSTALL LAG BOLTS 7' OF PORCH LEDGER INTO EXISTING 3) WILL CHECK AT INTERMEDIATE FRAME | |
| 07/12/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) REAR ADDITION: NAIL OFF ALL EXTERIOR SHEATHING AND COMPLETE SHEATHING INSTALLATION 2) INSTALL POSITIVE CONNECTION PORCVH BOTTOM PLATE TO STUDS 3) STUDS TO BEAM, BEAM TO PLATES, TOP AND BOTTOM CRIPPLE WALL ETC. 4) INSTALL BANG PLATES EXTERIOR PLATES AT PLUMBING CUTS 5) INSTALL BLOCKING AT LEDGERS 6) INSTALL HANGERS AROUND FIREPLACE ON SINGEL 2 X 12 AT BEARING NEED VERIFICATION OF PORCH LEDGER TO STUDS A35'S 7) STOPPED INSPECTION 8) WILL NEED TO RAISE FIREPLACE CHIMNEY 24" ABOVE PARAPET |
|
| 07/06/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :*/ 1) NEW FRONT COVERED ENTRY OK 2) REAR ADDITION NOT READY |