Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM00049
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/28/2007 | FRAMING | Approved | IVRS - Inspection :* | |
09/24/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PENDING ALL TRADES |
|
09/21/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NAIL PROTECT ELECT. THROUGHOUT 2. SECURE ROMEX 8" FROM BOXES THROUGHOUT 3. WATER TEST NEEDED DWV SYSTEM 4. NEED PROTECT PLUMBING THROUGHOUT 5. TERMINATE EXHAUSTION TO EXTERIOR 6. SECURE ROMEX EVERY 6' CEILING STOPPED INSPECTION |
|
09/17/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) COMPLETE ALL TRADES 2ND FLOOR PRIOR TO FRAME INSPECTION |
|
06/20/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 1ST FLOOR OK-2ND FLOOR PLUMBING MUST BE WATER TESTED |
|
06/12/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DRAIN/WASTE/VENT SYSTEM MUST HAVE WATER TEST TO ROOF 2) BLOCK DUCT BOOTS 3 SIDES 3) NARROW END OF STAIR WINDER MUST BE 6" 4) ELECTRIC BOX MISSING AT STAIR 5) FIRST FLOOR ONLY INSPECTED-SECOND FLOOR NOT READY 6) STAIR WINDER DEPTH LESS THAN 10" AT 12" FROM NARROW END |
|
04/10/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE OTHER TRADES PRIOR TO FRAME INSPECTION 2) FIRE BLOCK AT FURR OUT AT CEILING |
|
01/28/2005 | FRAMING | Partial Approval | IVRS - Inspection :*PA | |
09/10/2004 | FRAMING | Partial Approval | ||
09/08/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) FIREBLOCK AT SOFFIT 2) SECURE ELECTRIC 8" MINIMUM FROM BOX 3) PROTECT PLUMB THRU OUT 4) GROUND ALL LIGHT FIXTURE 5) PROVIDE CLEANOUTS AS PER PLAN 6) PROVIDE 1" CLEARANCE FOR W.H. FLU |
|
07/12/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PROVIDE FIRE AT FUR DOWN AT EAST WALL |
|
02/13/2004 | FRAMING | Denied | 1) COMPLETE ALL TRADES PRIOR TO FRAME INSPECTION 2) FIRE BLOCK MISSING AT FUR DOWN |