Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/01/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
02/26/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) REDO PATIO LEDGER STRAPS
02/25/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) 3, 5 6, AND 7 NOT DONE FROM LAST INSPECTION
02/23/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
02/20/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NAIL OFF SMALL HIP PIECE ON S.E. HIP 2) NAIL OFF EAST SIDE PARAPET ON REAR PORCH 3) STRAP ALL NON-CABIN TIED EXTERIOR TOP PLATES 4) 4) CUT VIEW HOLES IN BOTTOM OF FRONT COLUMNS 5) H2.5 S.E. AND S.W. HIP TRUSSES 6) EAST AND WEST REAR PORCH COLUMSN HAVE NOT ANCHOR BOLTS 7) PORCH LEDGERS ARE NOT CLIPPED 8) 1 WEST WINDOW NOT FRAMED YET
02/19/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*