Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/04/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/03/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROTECT GAS LINE PER UPC , NUT BY FITTING 2) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 3) NAIL OSB SHEAR TO BLOCK 4) HOLDOWN AND ABS |
| 03/01/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0399*/ 1) W/H "B" VENT REQURES 1" CLEARANCE TO COMBUSTIBLES 2) DUCT WORK NOT COMPLETE 3) GAS LINE NOT PROPERLY SUPPORTED 4) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 5) BACK GROUT TUB FLOOR PENETRATION 6) FIRBLOCK SHEAR BLOCK MISSING BY MASTER SHOWER RENAIL THRU STUCCO 7) SHEAR WALL 8 HOLDOWN BOLTS LOOSE 8) SHEAR WALL 8 REQUIRES 5/8" ANCHOR BOLTS 9) TRUSS BRACE RAT RUN MISSING 10) DWV WATER TEST OK |
| 02/25/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) INTERMEDIATE INSPECTIONS CANNOT BE MADE PRIOR TO LATH BEING INSTALLED AND PASSED |