Permit: T04CM00016

Parcel: 138242930


Addresses:

1950 W BELLAGIO DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/19/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
02/12/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0935*/ 1) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF WALL SURFACE 2) TRUSSES NOT BRACED PER TRUSS DRAWINGS. SEE ITEM 3 AND 7 FROM 2/10/04 AND 2/11/04 INSPECTIONS. YOU MUST PAY A REINSPECTION FEE PRIOR TO NEXT INSPECTION
02/11/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*1) TRUSS BRACING NOT INSTALLED 2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF WALL SURFACE 3) TRUSSES NOT CROSS BRACED AT 20 FT O.C.
02/10/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SHEAR WALL AT REAR MUST BE NAILED AT 4" ON CENTER AT ENDS AND EDGES 2) NORTH EAST HOLDOWN NAILED TO FULL LENGTH DOUBLE STUDS 3) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF WALL SURFACE 4) NORTH TRUSS NOT CLIPPED ON NORTH EAST CORNER 5) ALL OSB SHEAR WALLS NOT NAILED PER PLAN 6) OSB ROOF PANELS MUST SPAN 3 TRUSSES-TWO BAYS 7) TRUSSES A01M NOT BRACED PER TRUSS DRAWINGS 8) TRUSSED NOT CROSS BRACED AT 20 FEET ON CENTER PER TRUSS CALCS