Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - FINAL
Permit Number - T04BU03082
Inspection Description - GRADING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/30/2007 | GRADING - FINAL | Approved | ||
04/17/2007 | GRADING - FINAL | Partial Approval | 1. PROVIDE AN ORIGINAL COPY OF A LETTER OF CERTIFICATION FROM THE ARIZONA REGISTERED P.E. THAT CERTIFYS THAT THE PROJECT WAS CONSTRUCTED TO THE APPROVED GRADING PLAN AND THAT THE RETENTION/DETENTION BASIN AND DRAINAGE WILL FUNCTION AS DESIGNED. 2. PROVIDE CEMENT IN THE BOTTOM OF THE CATCH BASIN TO PREVENT WATER BELOW THE INVERTS OF THE 18" PIPES (KEYNOTE 34). 3. PROVIDE (2) STOP SIGNS A THE DRIVEWAY EXITS (KEYNOTE 28) 4. ADJUST UTILITY BOX TO GRADE NEAR NORTHEAST ENTRANCE (KEYNOTE 33). 5. BACKFILL AND COMPACT SOIL AT THE TOP OF THE RETENTION/DETENTION BASIN SPILLWAY (DETAIL 10 SEC B-B) 6. COMPLETE ALL EARTHEN DRAINAGE SWALES (KEYNOTE 30). 7. COMPLETE ALL SOIL STABILIZATION (KEYNOTE 25). 8. CONSTRUCT 6' WIDE D.G. PEDESTRIAN WALKWAY AT SOUTH PERIMETER. 9. COMPLETE STORMWATER HARVES BASIN NEAR SOUTHEAST CORNER OF SITE. 10. PROVIDE GRAVEL ON WEST PERIMETER TO MATCH GRADE OF WALL OPENINGS. 11. PATCH ASPHALT NEXT TO HANDICAP RAMP ON WYATT DR. |