Permit: T04BU03002


Addresses:

7681 E 22ND ST


Inspection Status: Approved

Inspection History: GRADING - INTERMEDIATE

Permit Number - T04BU03002

Inspection Description - GRADING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/07/2009 GRADING - INTERMEDIATE Approved READY TO CLOSE OUT
10/14/2008 GRADING - INTERMEDIATE Continued TALKED WITH MIKE GARDNER REGARDING SITE

NO FINISHED PAD ELEVATIONS WERE SHOT BY SURVEYORS

CHECKING WITH LOREN TO SEE IF THAT IS ACCEPTABLE
05/28/2008 GRADING - INTERMEDIATE Continued BORDERLAND DOING WATER LINE WORK IN ROW
SITE IS GETTING CLOSE TO BEING BUILT OUT
01/04/2008 GRADING - INTERMEDIATE Continued MET ONSITE WITH HOWARD MEYERS AND GREG MOHL

SEE PICS 2896-2909

CONCERNS REGARDING STEEP SLOPE
FINAL STABILIZATION ALONG EAST SIDE OF SITE
09/26/2007 GRADING - INTERMEDIATE Correction Required MET ONSITE WITH GREG MOHL (KB), ERIC CHENEY, MARTY MAGELLI AND HOWARD MEYERS
-OUTFALLS OF DRAINAGE WAYS ON EAST SIDE OF SITE WILL NEED TO BE ADDRESSED. MARTY MAGELLI TO TALK TO LOREN REGARDING REQUIREMENTS.
-WALKED SITE AND DISCUSSED SWPPP CONTROLS
-WALKED SITE AND DISCUSSED FINAL STABILIZATION REQUIREMENTS.
10/12/2006 GRADING - INTERMEDIATE Correction Required SEE PICS 1516-1524
08/15/2006 GRADING - INTERMEDIATE Correction Required SEE PICS 1026-1035
STILL DRAINAGE CONCERNS FOR LOS PORTALES
TALKED TO CANDY (PROPERTY MANAGER)
THERE HAS BEEN SOME DISCUSSION REGARDING A POSSIBLE FIX/COMPENSATION
I WILL CHECK WITH LOREN TO SEE IF ANY REVISIONS FOR THIS AREA HAVE BEEN RECEIVED.
07/05/2006 GRADING - INTERMEDIATE Partial Approval MET WITH LOREN, MARTY MAGELLI, KAMERON ON SITE

PAD HEIGHTS ARE AT BLUE TOP WITH THE EXCEPTION OF SOME THAT ARE NOW LOW

AS BUILT/REVISED DRAWINGS TO BE SUBMITTED AND APPROVED BY LOREN-PERMIT HOLDS TO BE REMOVED

ALSO SPOKE TO KAMERON AND MARTY ABOUT STABILIZATION BEHIND THE SIDEWALK IN COT ROW-PER KAMERON WHATEVER NEEDS TO BE DONE

SPOKE TO KAMERON AND MARTY ABOUT EROSION/RUNOFF INTO PROPERTY TO THE NORTH
MARTY TO ENGINEER A FIX
06/14/2006 GRADING - INTERMEDIATE Correction Required MET ON SITE WITH BRUNO
NO ELEVATIONS HAVE BEEN PROVIDED TO HIM

SWPPP MAINT SVCS ON SITE DOING SWEEPING
OIL LEAK WAS TO BE CLEANED UP BY A LABORER

LEFT PHONE MESSAGE FOR KAMERON-NO RETURN CALL YET
06/14/2006 GRADING - INTERMEDIATE Correction Required SPOKE TO KAMERON
PADS ARE NOT TO GRADE
THE INTENTION IS TO AS BUILT THE PAD HEIGHTS
I EXPLAINED TRANSPORTATION'S CONCERN ABOUT DIRT FALLING OVER SIDEWALK AND THE SUBSEQUENT NEED FOR STABILIZATION
06/06/2006 GRADING - INTERMEDIATE Correction Required MADE SITE VISIT
SPOKE TO BRUNO-REVISED GRADING PLAN NOW ON SITE
BRUNO IS UNAWARE OF ANY COMPLETION PROGRESS FOR ELEVATION SHOTS
I HAVE LEFT A MESSAGE FOR CAMERON WITH KB LAND DEPT
05/26/2006 GRADING - INTERMEDIATE Correction Required MET WITH CAMERON (KB), MARTIN (COT), BRUNO (KB)
PADS ARE NOT AT BLUE TOP AS HAD BEEN PREVIOUSLY REPORTED TO MARTIN
CONCERNS ABOUT GRADE AT SIDEWALK HAS BEEN ADDRESSED
LOREN HAS PUT A HOLD ON ALL PERMITS UNTIL KB PROVIDES SPOT ELEVATIONS
CAMERON IS TO PROVIDE SITE SUPER WITH A SET OF GRADING PLANS AS THERE ARE NONE ON SITE WITH THE MOST RECENT REVISION
05/23/2006 GRADING - INTERMEDIATE Correction Required GAVE BRUNO MY OLDER SET OF GRADING PLANS
PER BRUNO NONE WERE ON SITE
SPOKE TO MARTIN (COT CONST INSP) AND ADVISED PAD GRADES DO NOT APPEAR TO BE AS SET ON GRADING PLAN
I ALSO ADVISED BRUNO (KB HOMES) THAT PAD GRADES APPEAR NOT TO BE SET AS CALLED OUT IN GRADING PLANS