Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA PRE-GUNITE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2005 | POOL/SPA PRE-GUNITE | Approved | IVRS - Inspection :* | |
| 01/10/2005 | POOL/SPA PRE-GUNITE | Partial Approval | IVRS - Inspection :* 1) POOL PLAN MUST SPECIFY SPECIAL ATMOSPHERIC VACCUM RELIEF SYSTEM TO BE INSTALLED 2) DRAIN SUCTION LINES HAVE BEEN COVERED WITHOUT INSPECTION AND A PRESSURE TEST WITH WATER APPLIED. PROVIDE AN AIR PRESSURE TEST WITHOUT WATER FOR SUCTION LINES 3) YOU MUST SCHEDULE PLUMBING AND ELECTRIC INSPECTIONS. DO NOT COVER PLUMBING AND ELECTRIC 4) POOL BOND AND REBAR OK TO GUNITE 5) WE CANNOT INSPECT ITEMS THAT HAVE NOT BEEN REQUESTED |
|
| 01/06/2005 | POOL/SPA PRE-GUNITE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DUEL DRAIN OUTLETS MUST BE SUPPORTED BY A MINIMUM OF 36" PER IRC AG-106.4 2) PROVIDE A COMPLETE APPROVED PLUMBING PLAN SHOWING ALL VALVES, PUMPS AND ATMOSPHERIC VACCUM RELIEF SYSTEM INSTALLATION PER IRC AG-106 3) YOU MUST CALL IN ALL REQUIRED INSPECTIONS FOR PRE GUNITE INCLUDING, PLUMBING AND ELECTRIC |