Permit: T04BU02927

Parcel: 116276130

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Date Description Inspector Results Comments
03/28/2005 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
03/22/2005 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POOL NOT TO BE FILLED WITH WATER UNTIL FINAL APPROVAL. POOL FILLED WITH WATER
2) DBL GATE NOT ALLOWED TO OPEN, ONE GATE MUST BE PERMANENTLY CLOSED
3) PATIO WALL CONSTITUTES A FOOT HOLD TO CLIMB OVER WROUGHT IRON SECTION AG 105 SECTION B SUB. SECTION 4
4) TEMP RELIEF VALVE AT HEATER MUST TERMINATE 6" FROM FINISHED GRADE
03/04/2005 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) YOU HAVE OBTAINED A WAIVER FROM DAVE MANN TO USE DRAFT CODE WHICH STATES IN PARAGRAPH 3 THAT NO PORTION OF THE BLDG CAN BE USED AS A ?. COMPLY WITH EITHER PARAGRAPH 3A OR 3B
2) TRIED CALLING BOTH PHONE NUMBERS TO INFORM POOL CO. BUT BOTH VOICE MAILS WERE FULL
03/02/2005 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIXED PANEL GATE MUST BE PAD LOCKED
2) INSIDE OF HOUSE DOORS AND WINDOWS OK
3) EXTERIOR BARRIER HAS GAPS LARGER THAN 4"
4) ATMOSPHERIC VACCUM RELIEF DOES NOT COMPLY WITH 2003 IRC REVISED SEP 2004. IF YOU DESIRE TO UTILIZE PROPOSED REVISION DRAFT YOU MUST HAVE BLDG OFFICIAL APPROVAL
12/21/2004 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEM 2 OF 12/12/04 NOT COMPLIED WITH