Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA PRE-GUNITE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/06/2005 | POOL/SPA PRE-GUNITE | Approved | IVRS - Inspection :* | |
| 12/21/2004 | POOL/SPA PRE-GUNITE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POOL HEATER REQUIRES TEMP/PRESSURE RELIEF VALVE 2) YOUR PLAN DOES NOT INCLUDE A PLUMBING PLAN OR AN APPROVED DESIGN OF THE ATMOSPHERIC VACCUM RELIEF SYSTEM REQUIRED BY 2003 IRC SECTION AG 106 3) PROVIDE GAS LINE SIZE AND LENGTH ON PLAN AND HEATER DEMAND 4) ELECTRIC CONDUIT AND BONDS OK WIRES NOT PULLED 5) 3" CLEARANCE REQUIRED BETWEEN REBAR AND ? 6) PROVIDE APPROVED DESIGN FOR NEGATIVE EDGE AT SPA 7) SPA SPILL WAY REQUIRES 3-#3 BARS EACH SIDE DETAIL 6 8) 1 1/2" CLEARANCE REQUIRED BETWEEN PLUMBING AND REBAR |