Permit: T04BU02662

Parcel: 12907006S


Addresses:

1563 E 36TH ST


Inspection Status: Approved

Inspection History: POOL/SPA PLUMBING

Permit Number - T04BU02662

Inspection Description - POOL/SPA PLUMBING

Inspection Status - Approved

Date Description Inspector Results Comments
02/22/2006 POOL/SPA PLUMBING Approved IVRS - Inspection :*
12/08/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*
6" SCH 40 PVC WATER LINE TO SLIDE - 53 PSI -- OK
12/06/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*3/4 PVC SCH 80 UNDERGROUND WATER LINE TO H'CAP LIFT PUMP OK
EXPOSED PIPING SHALL BE PROTECTED FROM UV RAYS
PIPING TO BACKFLOW ASSEMBLY SHALL BE FULL SIZE.
BACKFLOW ASSEMBLY REQUIRES A UNION AND CERTIFICATION.
08/17/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*
1) 50 PSI TEST ON 6" EQUALIZER PIPING AND 50 PSI TEST ON 1" WHEEL CHAIR LIFT LINE OK
08/11/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*
1) ALL PIPING TO SPRAY COURT AND POOL 50 PSI TEST OK
2) 6" SLIDE SUPPLY STUBBED TO POINT ON PLAN PER INITAL
3) 1" H20 TO ADDED WHEEL CHAIR LIFT 50 PSI TEST OK-PENDING PROPER BACKFLOW PROTECTION
4) 1 NEED TO SEE 6" SLIDE CONTINUATION AND MECH PODS COMPLETION
08/10/2005 POOL/SPA PLUMBING Cancelled IVRS - RI canceled
07/14/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :* 1 1/2" TO (4) GROUND SPRAYS 35 & P SI TEST TO SOUTHEAST CORNER OF POOL OK
07/08/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :* 50 PSI TEST ON 2 1/2" BALANCE LINE REPAIR OK
07/07/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :* (4) 1 1/2 VORTEX LINES COMPLETED 50 PSI TEST OK. 10" GUTTER DOWN TO 8'' TO (3) GUTTER SUCTIONS. 50 PSI TEST OK. 2 1/2 BALANCE LINE TO 3" FROM POOL 50 PSI TEST OK. 2 1/2 WALL RETURN TO ( 4) 1 1/2 INLETS 50 PSI TEST OK. 1) NEED TO REPAIR LEAK ON 2 1/2 BALANCE LINE 2' FROM EQUIPMENT ROOM NORTH WAL. 2" FILL LINE TO TERMINATION AT POOL 50 PSI TEST OK
06/15/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :* 1) 50 PLUS AIR PRESSURE TEST IS OK. FOR UNDERGROUND POOL PIPING IS OK AS INITIALED ON PLAN.
06/09/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*
1) 50 PLUS PSI WATER TEST PER HIGHLIGHTED INITALED PLAN IN TRAILER ON ZERO ENTRY POOL
06/08/2005 POOL/SPA PLUMBING Not ready for Inspection IVRS - Inspection :*
06/02/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :* / ALL UNDERGROUND PIPING FROM MECH ROOM PAGE PP1.1 TO 10' TOWARD POOL 50 PSI TEST OK PER APPROVED PLAN PP1.1