Permit: T04BU02492

Parcel: 125170170

Inspection Status: Partial Approval

Inspection History: POOL/SPA FINAL/BARRIER

Date Description Inspector Results Comments
12/09/2004 POOL/SPA FINAL/BARRIER Partial Approval IVRS - Inspection :*
1) NEED APPROVED ATMOSPHERIC VACCUM RELIEF SYSTEM INSTALLED PER 2003 IRC SEC. AG 106.3
2) OBTAIN APPROPRIATE CITY OF TUCSON APPROVED DESIGN AND LISTINGS
3) INSTALL APPROVED DEVICE-DEVICES
4) RECALL FOR FINAL
5) OK TO PLASTER SPA
12/08/2004 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO RECORD OF 08040 APPROVAL ?
2) 08035 AND 08030 PARTIALED-RECALL ?
3) NO GAPS LARGER THAN 4" UNDER METAL FENCE
4) NEED APPROVED ATMOSPHERIC VACCUM RELIEF SYSTEM PER 2003 IRC AG 106.3
5) STOPPED INSPECTION
12/07/2004 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GATE MUST SELF LATCH
2) HEATER MISSING REQUIRED PRESSURE RELIEF VALVE
12/06/2004 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) GATE MUST OPEN AWAY FROM POOL AREA
2) ANTI SUCTION DEVICE REQUIRED PER IRC