Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/10/2005 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* | |
| 05/03/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* ITEMS 1 & 2 FROM 4/26/05 INSPECTION NOT COMPLIED WITH |
|
| 04/26/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 9 FEET OF EAST END OF NORTH WALL IS LESS THAN 5 FEET HIGH ON OPPOSITE SIDE 2) ANTI-VORTEX SUCTION INLETS MUST BE 36" APART. LINES ARE PRESENTLY 32 1/2" APART. PROVIDE PIPE TO ANTI-VORTEX COVERS ADAPTERS AND ANTI-VORTEX COVERS ALONG WITH THEIR INSTALLATION INSTRUCTIONS AND PUMP CAPACITY 3) PROVIDE ATMOSPHERIC VACCUM RELIEF SYSTEM PER 2003 IRC SECTION AG106 |