Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/15/2004 |
ROOF NAILING |
|
Approved |
IVRS - Inspection :* |
| 11/09/2004 |
ROOF NAILING |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) ROOF SHEATHING: SHEETS ARE TO BE INSTALLED PERPENDICULAR TO RAFTERS. YOU CAN REMOVE AND TURN SHEETS AROUND OR BLOCK AT 24" ON CENTER BETWEEN RAFTERS, MAKING SURE TO BLOCK UNDER ENDS OF SHEETS, NO STRENGTH IN PLY THE WAY IT'S INSTALLED |
| 11/02/2004 |
ROOF NAILING |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) GO AHEAD AND PUT ON ROOF SHEATHING, NAIL EDGES AT 6" ON CENTER AND 12" IN THE FIELD. THEN CALL IN FOR ROOF NAIL INSPECTION AND FINAL. I DON'T INSPECT ROOFING, YOU CAN DO THAT AFTER SHEATHING INSPECTION |