Permit: T04BU02367

Parcel: 141304440

Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T04BU02367

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
11/15/2004 ROOF NAILING Approved IVRS - Inspection :*
11/09/2004 ROOF NAILING Not ready for Inspection IVRS - Inspection :*/ 1) ROOF SHEATHING: SHEETS ARE TO BE INSTALLED PERPENDICULAR TO RAFTERS. YOU CAN REMOVE AND TURN SHEETS AROUND OR BLOCK AT 24" ON CENTER BETWEEN RAFTERS, MAKING SURE TO BLOCK UNDER ENDS OF SHEETS, NO STRENGTH IN PLY THE WAY IT'S INSTALLED
11/02/2004 ROOF NAILING Not ready for Inspection IVRS - Inspection :*/ 1) GO AHEAD AND PUT ON ROOF SHEATHING, NAIL EDGES AT 6" ON CENTER AND 12" IN THE FIELD. THEN CALL IN FOR ROOF NAIL INSPECTION AND FINAL. I DON'T INSPECT ROOFING, YOU CAN DO THAT AFTER SHEATHING INSPECTION