Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - FINAL
Permit Number - T04BU02245
Inspection Description - GRADING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/14/2005 | GRADING - FINAL | Approved | ||
06/07/2005 | GRADING - FINAL | Denied | 1. PROVIDE A PIPE BOLLARD IN FRONT OF THE ROOF DRAIN AT THE JIB CRANE AREA TO PREVENT STORAGE IN FRONT OF THE ROOF DRAIN OPENING. 2. PROVIDE AN ASPHALT BERM AT THE SOUTHEAST CORNER OF THE LOADING DOCK TO PREVENT RAINWATER FROM THE ROOF DRAIN DISCHARGE TO FLOW INTO THE DOCK AREA. 3. INSPECTOR WILL VERIFY ACCEPTANCE OF THE STORMWATER/DRY WELL LETTER. |
|
05/16/2005 | GRADING - FINAL | Denied | SEE PREVIOUS COMMENTS FOR INSPECTION ON 5/2/05. IN ADDITION: PROVIDE PIPE BOLLARDS IN FRONT OF ROOF DRAIN OPENINGS TO PREVENT BLOCKAGE OF DISCHARGE. ROOF DRAIN OPENINGS SHOULD NOT BE BLOCKED BY STORAGE OF BALED CARDBOARD. |
|
05/02/2005 | GRADING - FINAL | Denied | 1. COMPLETE ALL STRIPING AND TRAFFIC ARROWS AT ALL DRIVEWAY ENTRANCES. 2. INSPECT AND REPAIR DRYWELLS PER GRADING PLAN NOTE #4, PAGE C-2. PROVIDE AN ENGINEERS CERTIFICATE OF PROPER OPERATION. 3. GRADE TREE ISLANDS 2" BELOW PARKING LEVEL PER NOTE X, PAGE C-1. 4. REPAIR ASPHALT AT ELECTRICAL EXCAVATION NORTH OF BUILDING. 5. PROVIDE (8) BICYCLE LOCKERS AS SHOWN ON THE PLAN. |
|
03/25/2005 | GRADING - FINAL | Denied | NOT READY FOR INSPECTION. COMPLETE ALL SITE WORK. |