Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA PRE-GUNITE
Permit Number - T04BU02116
Inspection Description - POOL/SPA PRE-GUNITE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/07/2004 | POOL/SPA PRE-GUNITE | Approved | IVRS - Inspection :*/ 1) OK GUNITE 2) ELECTRIC HOMERUNS NOT INSTALLED | |
09/03/2004 | POOL/SPA PRE-GUNITE | Not ready for Inspection | IVRS - Inspection :*/ 1) AT H20 SUPPLY CU. TO GALV. NOT ALLOWED, NEED BRASS FITTING OR DIELECTRIC UNION, INSTALL VAC. BREAKER 2) AT WATER FEATURE REBAR PER DETAIL IS 6" ON CENTER ON THE FLR 3) MAINTAIN 2" CLR REBAR TO EARTH AT H20 FEATURE 4) NO HOME RUNS INSTALLED AT THIS TIME |