Permit: T04BU02089

Parcel: 125072360


Addresses:

2245 E 6TH ST

Inspection Status: Approved

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
10/13/2004 POOL/SPA PRE-GUNITE Approved IVRS - Inspection :*
10/12/2004 POOL/SPA PRE-GUNITE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) RE-INFORCING STEEL MUST HAVE 1 1/2" CLEARANCE TO FORMS 2) NEGATIVE EDGE POOL REQUIRES DBL RACK OF STEEL. SEE DETAIL UPPER LEFT OF S-2 3) IF POOL AREA IS TO BE BACKFILLED TO POOL DEPTH THEN EXISTING MASONRY WALL WILL HAVE TO BE ENGINEERED AS A RETAINING WALL
10/07/2004 POOL/SPA PRE-GUNITE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) PLAN CALLS FOR DBL #4 BOND BEAM AT TOP OF FREE STANDING POOL WALL 2) PARTIAL ON PLUMBING/ELECTRIC PENDING FINAL