Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA PLUMBING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/25/2005 | POOL/SPA PLUMBING | Approved | IVRS - Inspection :* | |
| 02/17/2005 | POOL/SPA PLUMBING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) AUTOFILL CROSS CONNECTION PREVENTION DEVICE MUST BE A TESTABLE DEVICE. INSTALLED CHECK VALVE NOT ALLOWED 2) ATMOSPHERIC VACCUM RELIEF SYSTEM NOT INSTALLED 3) ANTI-VORTEX DRAINS NOT INSTALLED. MUST BE 36" BETWEEN DRAINS 4) NO PLANS OR PERMIT ON SITE. YOU MUST COMPLY WITH 2003 IRC SEPT OF AMMENDMENTS OR FILE AN APPEAL TO THE BLDG OFFICIAL TO USE PORTIONS OF DRAFT AMMENDMENT 5) POOL ENCLOSURE MUST BE 5 FEET HIGH |
|
| 10/15/2004 | POOL/SPA PLUMBING | Partial Approval | IVRS - Inspection :*/ 1) INTERIOR POOL AREA |