Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04BU01983

Parcel: 140375730


Addresses:

5929 E CEDARBIRD DR

Inspection Status: Approved

Inspection History: POOL/SPA PLUMBING

Date Description Inspector Results Comments
02/25/2005 POOL/SPA PLUMBING Approved IVRS - Inspection :*
02/17/2005 POOL/SPA PLUMBING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) AUTOFILL CROSS CONNECTION PREVENTION DEVICE MUST BE A TESTABLE DEVICE. INSTALLED CHECK VALVE NOT ALLOWED
2) ATMOSPHERIC VACCUM RELIEF SYSTEM NOT INSTALLED
3) ANTI-VORTEX DRAINS NOT INSTALLED. MUST BE 36" BETWEEN DRAINS
4) NO PLANS OR PERMIT ON SITE. YOU MUST COMPLY WITH 2003 IRC SEPT OF AMMENDMENTS OR FILE AN APPEAL TO THE BLDG OFFICIAL TO USE PORTIONS OF DRAFT AMMENDMENT
5) POOL ENCLOSURE MUST BE 5 FEET HIGH
10/15/2004 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*/ 1) INTERIOR POOL AREA