Permit: T04BU01954

Parcel: 118037660

Inspection Status: Approved

Inspection History: POOL/SPA PLUMBING

Date Description Inspector Results Comments
10/08/2004 POOL/SPA PLUMBING Approved IVRS - Inspection :*
08/31/2004 POOL/SPA PLUMBING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SEE ITEMS FROM PRIOR INSPECTION 2) DO NOT COVER PLUBMING ELECTRIC FROM PUM TO FRONT OF HOUSE
08/27/2004 POOL/SPA PLUMBING Denied IVRS - Inspection :WINDOWS DO NOT NEED TO COMPLY UNTIL FINAL INSPECTION BUT ALL OTHER ITEMS EXCEPT ITEMS 3 & 4 OF 8-18-04 INSPECTION HAVE NOT BEEN COMPLIED WITH
NEXT FAILURE MAY BE CHARGED A RE-FEE
08/18/2004 POOL/SPA PLUMBING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) ELECTRIC PLASTIC CONDUIT MUST BE 18" BELOW GRADE 2) WINDOWS WITHIN 5 FEET OF POOL MUST BE SAFETY GLAZED 3) REINFORCING STEEL IS NOT PER PLAN IN SURCHARGE AREA OF HOUSE 4) DETAIL Q OF PLAN NOT COMPLIED WITH AT LIGHT 5) REBAR TOO FAR APART ON NORTH WALL 6) 1 1/2" CLEARANCE REQUIRED BETWEEN PLUMBING AND REBAR 7) BLACK PIPE NIPPLE NOT ALLOWED IN AUTOFILL WATER SYSTEM POTABLE SIDE 8) WATER LINE MUST BE 12" BELOW GRADE