Date Description Inspector Results Comments
04/30/2012 GRADING - TIER REV Approved
08/09/2011 GRADING - TIER REV Correction Required WENT TO THE SITE WITH MIKE RUSSO AND LOOKED OVER THE LIST OF CONCERNS RAISED BY THE REVIEW STAFF. WILL DISCUSS ANY REMAINING CONCERNS WITH THE ENGINEERING REVIEWER TOMORROW MORNING SO THE FINAL REVISIONS CAN BE APPROVED.
06/03/2010 GRADING - TIER REV Correction Required For release of lot 2, the following 6 items need to be completed by a City of Tucson approved deadline:
a) Remove sediment control measures from basin, channels, scupper inlets.
b) The offsite north channel that conveys drainage from this subdivision's north lots shall be regraded to match the approved Silverbell Trails channel configuration.
c) After the offsite north channel is regraded, as-built elevations shall be provided with the revised grading plan set to show that the channel is graded to match the approved Silverbell Trails channel geometry and show positive gradient from the end of the channel near lot 18 toward Silverbell Road.
d) Elevation profile along west property boundary at west inlet structures shall be verified for conveyance for anticipated 100-year floodplain condition. Provide a drainage discussion, and if necessary, proposed revised design to address prevention of potential erosion at either end of concrete weir.
e) Provide percolation test for Northeast basin. This percolation test must be post-construction - not the design testing rate. There are indications and observations that this basin exceeds drain down time per City standards therefore a post-construction percolation test is required.
f) Provide erosion protection in swale west of lot 18 from existing placed gravel near front of lot to northwest corner of lot 18 at offsite north channel.
05/08/2009 GRADING - TIER REV Approved Contractor Bob Martinez and developer Keith Davern stated that the RGP was expected to be submitted soon. Also SWPPP controls to be installed for SWPPP follow-up inspection by 15MAY09.