Inspection Status: Approved
Inspection History: POOL/SPA GAS
| Date |
Description |
Inspector |
Results |
Comments |
| 03/23/2005 |
POOL/SPA GAS |
|
Approved |
IVRS - Inspection :* 1) APPROVED PLAN ON SITE. CONTRACTOR TO REDLINE GAS ROUTING CHANGE |
| 03/22/2005 |
POOL/SPA GAS |
|
Not ready for Inspection |
IVRS - Inspection :* 1) JOBSITE TRAILER HAS BEEN REMOVED. UNABLE TO LOCATE PLAN OR PERMIT. 2) FEMALE PVC THREADED FITTINGS ARE PROHIBITED ON WATER PIPING. 3) PVC WATER PIPING EXPOSED EXTERIOR LOCATION NOT PERMITTED ( ALSO IT IS LEAKING) |
| 02/16/2005 |
POOL/SPA GAS |
|
Not ready for Inspection |
IVRS - Inspection :* NOT READY |
| 11/24/2004 |
POOL/SPA GAS |
|
Partial Approval |
1)WILL REQUIRE REVISED APPROVED PLAN SHOWING METER RELOCATE TO POOL EQUIPMENT AREA; AND NEW ROUTING OF BBQ GAS-REDLINES ON SITE. OK TO COVER |
| 11/23/2004 |
POOL/SPA GAS |
|
Not ready for Inspection |
IVRS - Inspection :*/1)BBQ GAS NOT ON PLAN - REMEMBER, IF 3/4" PLASTIC GAS IS APPROVED FOR BBQ ALL UNSLEEVED GAS TO BE SHADED AND BEDDED IN SAND. 2)REVISE PLAN FOR NEW LAYOUT. INCLUDE GAS ISOMETRIC SHOWING TOTAL BTU AND DEVELOPED LENGTH |
| 11/22/2004 |
POOL/SPA GAS |
|
Not ready for Inspection |
IVRS - Inspection :* |