Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04BU01387

Parcel: 112050570


Addresses:

3109 N OLSEN AV


Inspection Status: Approved

Inspection History: STORMWATER INSTALL OF CONTROLS

Permit Number - T04BU01387

Inspection Description - STORMWATER INSTALL OF CONTROLS

Inspection Status - Approved

Date Description Inspector Results Comments
12/01/2004 STORMWATER INSTALL OF CONTROLS Approved
11/24/2004 STORMWATER INSTALL OF CONTROLS Cancelled
10/27/2004 STORMWATER INSTALL OF CONTROLS Correction Required PROVIDE SEDIMENT AND EROSION CONTROL AT THE WALL OPENINGS ON THE WEST PERIMETER
10/07/2004 STORMWATER INSTALL OF CONTROLS Not ready for Inspection I REVIEWED THE SWPPP WITH JERRY BELL (520) 990-6432.
1. POST SIGN WITH AZPDES AUTHORIZATION ETC... PER PART IV J. 2.
2. PROVIDE A CONCRETE WASHOUT AREA
3. PROVIDE A STABILIZED CONSTRUCTION ENTRANCE.
4. PROVIDE PERIMETER SEDIMENT AND EROSION CONTROLS.
5. CALL FOR INSPECTION OF STORMWATER CONTROLS BEFORE GRUBBING THE ENTIRE SITE.
09/07/2004 STORMWATER INSTALL OF CONTROLS Not ready for Inspection I MET WITH APRIL ORTIZ AND DAN MORITZ (241-8475) OF PATHWAYS DEVELOPMENT. THIS INSPECTION WAS DONE IN CONJUNCTION WITH THE NPPO INSPECTION. MR. MORITZ WILL NOTIFY MICHEAL BARTLETT TO SET UP A STORMWATER PRE-CONSTRUCTION MEETING.