Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Approval
Inspection History: GRADING - FINAL
Permit Number - T04BU01124
Inspection Description - GRADING - FINAL
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/17/2004 | GRADING - FINAL | Partial Approval | COMPLETE ITEMS #1 AND #2 AS NOTED ON THE PREVIOUS INSPECTION | |
09/15/2004 | GRADING - FINAL | Denied | SEE PREVIOUS COMMENTS | |
05/18/2004 | GRADING - FINAL | Denied | 1. PROVIDE (4) 2' CURB CUTS AND GRADE TREEWELLS TO ACCEPT/RETAIN STORMWATER RUN-OFF AT NORTH SIDE OF CHIPSEALED PARKING AREA. 2. GRADE PATIO AND ROOF DRAINS TO TREE WELLS TO ACCEPT/RETAIN STORMWATER RUN-OFF AT NORTH SIDE OF PROJECT. 3. PROVIDE SLOPE STABILIZATION (ROCK RIP-RAP) AT THE CORNER OF THE SIDEWALK AT THE NORTHWEST CORNER OF THE BUILDING. 4. ROOF DRAINAGE FLOWS ACROSS FRONT SIDEWALK ACCESS ON EAST SIDE OF THE BUILDING. PROVIDE SIDEWALK SCUPPERS PER C.O.T. DEVELOPMENT STANDARD NO. 2-08. 5. CLEAN UP AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS IN NATURAL DESERT AREAS EAST AND SOUTH OF CHIPSEALED PARKING AREA. 6. SUBMIT A REVISED GRADING PLAN TO C.O.T. ENGINEERING DIVISION THAT SHOWS THE RELOCATION OF BASKETBALLL COURT, AND THE ELIMINATION OF THE WEST PARKING LOT AND RETENTION BASIN. |