Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
Permit Number - T04BU00616
Inspection Description - POOL/SPA FINAL/BARRIER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/07/2004 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* | |
06/11/2004 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) INSTALL BOND WIRES TO METAL FENCING BOTH SIDES OF GATE 2) GATES TO SELF CLOSING LATCHING 3) NO GAPS LARGER THAN 4" UNDER FENCE 4) PROVIDE PROOF OF UNDERGROUND AND ALL ELECTRIC INSPECTION OR EXPOSE ALL 5) POOL BARRIER NOT INSTALLED PER PLAN 6) LATCHES TO BE 54" ABOVE WALKING SURFACE 7) HOSE BIB ANTI-SIPHON 8) OUTSIDE TO BE GFCI PROTECTED 9) STOPPED INSPECTION |
|
06/03/2004 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) POOL ENCLOSURE GATE MUST BE SELF CLOSING AND LATCHING 2) GATE LATCHES MUST BE 54" AND ABOVE GRADE 3) DOUBLE PANEL VEHICLE GATES NOT ALLOWED OR MUST COMPLY WITH ITEM 1 ABOVE 4) PROVIDE PROOF OF UNDERGROUND AND ALL ELECTRIC INSPECTION OR EXPOSE 5) POOL BARRIER NOT INSTALLED PER PLAN 6) WINDOWS CANNOT EGRESS INTO POOL AREA 7) HOSE BIB REQUIRES ANTI-SIPHON VALVE 8) OUTSIDE OUTLETS MUST BE GFCI PROTECTED |