Inspection History Details
Inspection Status: Denied
Inspection History: GRADING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/27/2004 | GRADING - FINAL | Denied | 1) PROVIDE AS-BULT DRAWINGS FOR ALL CHANGES THAT HAVE BEEN MADE TO THIS SITE, THIS WILL INCLUDE FOR ALL DRAINAGE WAYS AND SIDEWALKS. 2) COMPLETE THE BASIN AS SHOWN ON THE APPROVED PLANS: A)SHOW NEW METAL GRATES WITHIN THE PIPES B) SIZE THE BASIN AS SHOWN OR PROVIDE CALCULATIONS VERIFYING THAT THE MINIMUM REQUIREMENTS HAVE BEEN MET. C) INSTALL ROCK RIPRAP AS SHOWN ON THE APPROVED PLANS ALONG THE NORTH SLOPE AND IN THE BASIN BOTTOM.(CLEAN PIPES AS NEEDED) 3) REPAIRS SIDEWALKS AS NEEDED. |