Inspection History: POOL/SPA FINAL/BARRIER
Permit Number - T04BU00449
Inspection Description - POOL/SPA FINAL/BARRIER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/09/2004 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* | |
06/07/2004 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO POOL LATCH MUST BE 54" HIGH MINIMUM 2) NO APPARENT BOND WIRE ON FENCE WITHIN 5' OF POOL WATER 3) GAS PRESSURE OK, HOWEVER PIPE VERTICALS, AT THE HEATER AND METER, MUST BE TAPED WHERE SCOTCH COAT HAS BEEN SCRAPED OFF |