Permit: T04BU00374

Parcel: 133502590

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Permit Number - T04BU00374

Inspection Description - POOL/SPA FINAL/BARRIER

Inspection Status - Approved

Date Description Inspector Results Comments
05/19/2004 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
05/18/2004 POOL/SPA FINAL/BARRIER Partial Approval IVRS - Inspection :*/ 1) FROM LAST INSPECTION, WET-NICHE FIXTURE BOND CONNECTION TO BE ENCAPSULATED WITH POTTING COMPOUND SILICONE IS NOT POTTING COMPOUND 2) SCHEDULE 80 PVC AT SERVICE PANEL. WHERE THE METER IS EAST SIDE OF HOUSE
05/13/2004 POOL/SPA FINAL/BARRIER Not ready for Inspection IVRS - Inspection :*/ 1) WET NICHE FIXTURE BOND CONNECTION NOT ENCAPSULATED WITH POTTING COMPOUND 2) 4" TO EARTH AT POOL ENCLOSURE, DIRT WILL BE TO EASILY PUSHED AWAY FROM SLOPING BANK. YOU WILL NEED TO HAVE A PERMANENT BARRIER THERE 3) WIRE FENCE AFFORDS A HAND/FOOT HOLD, USE VERTICAL SLATS OR REMOVE 4) USE SCHEDULE 80 OVER METALLIC CONDUIT AT SERVICE AND J-BOX