Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
Permit Number - T04BU00374
Inspection Description - POOL/SPA FINAL/BARRIER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/19/2004 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* | |
05/18/2004 | POOL/SPA FINAL/BARRIER | Partial Approval | IVRS - Inspection :*/ 1) FROM LAST INSPECTION, WET-NICHE FIXTURE BOND CONNECTION TO BE ENCAPSULATED WITH POTTING COMPOUND SILICONE IS NOT POTTING COMPOUND 2) SCHEDULE 80 PVC AT SERVICE PANEL. WHERE THE METER IS EAST SIDE OF HOUSE | |
05/13/2004 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :*/ 1) WET NICHE FIXTURE BOND CONNECTION NOT ENCAPSULATED WITH POTTING COMPOUND 2) 4" TO EARTH AT POOL ENCLOSURE, DIRT WILL BE TO EASILY PUSHED AWAY FROM SLOPING BANK. YOU WILL NEED TO HAVE A PERMANENT BARRIER THERE 3) WIRE FENCE AFFORDS A HAND/FOOT HOLD, USE VERTICAL SLATS OR REMOVE 4) USE SCHEDULE 80 OVER METALLIC CONDUIT AT SERVICE AND J-BOX |