Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04BU00267

Parcel: 11515313B


Addresses:

826 W CALLE VENTURA

Inspection Status: Denied

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
03/10/2004 POOL/SPA PRE-GUNITE Denied IVRS - Inspection 0999*/ 1) REVISE SETBACKS TO SHOW ACTUAL FROM PROPERTY LINE TO EXCAVATION
03/10/2004 POOL/SPA PRE-GUNITE Approved IVRS - Inspection 0000*
03/08/2004 POOL/SPA PRE-GUNITE Denied IVRS - Inspection 0999*/ 1) REMOVE ROOTS FROM SIDE WALLS, BOTTOM 2) SEPERATE DRIVEN RODS FROM POOL STEEL 3) INSTALL DRIP LEG AT HEATER 4) PROVIDE DATA ON POOL HEATER 5) ID PROPERTY LINES 6) REMVOE ROCKS AT PVC AND SHADE WITH MAXIMUM 3/16" GRAVEL/SAND 7) 3" CLEARANCE AT SIDE WALLS/ BOTTOM TO STEEL