Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04BU00052

Parcel: 13216647A


Addresses:

900 E MACARTHUR CI


Inspection Status: Approved

Inspection History: ENGINEERING PRE-CONSTRUCTION

Permit Number - T04BU00052

Inspection Description - ENGINEERING PRE-CONSTRUCTION

Inspection Status - Approved

Date Description Inspector Results Comments
01/20/2005 ENGINEERING PRE-CONSTRUCTION Approved
07/08/2004 ENGINEERING PRE-CONSTRUCTION Partial Approval TEMPORARY APPROVAL.
1. PRECONSTRUCTION MEETING WITH DAVE MATHIS, DISSCUSSING SWPPP CONTROL INSTALLATION, (SILT FENCING,STABILIZED CONSTRUCTION ENTRANCE AND CONCRETE WASH OUT). ADVISED DAVE OF THE STANDARDS INVOLVED FOR REGULAR INSPECTIONS AFTER HEAVLY RAIN FALL.
2. REQUESTED RE-INSPECTION (#9152) AFTER SWPPP CONTROLS HAVE BEEN INSTALLED.
06/22/2004 ENGINEERING PRE-CONSTRUCTION Not ready for Inspection This site is still not ready for an inspection. Re-scheduled for July, 8th.
06/04/2004 ENGINEERING PRE-CONSTRUCTION Partial Approval This site has not began grading at this time.