Permit: T04BU00025

Parcel: 133092770


Addresses:

2220 N HAYDEN DR


Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Permit Number - T04BU00025

Inspection Description - POOL/SPA FINAL/BARRIER

Inspection Status - Approved

Date Description Inspector Results Comments
05/26/2004 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
05/21/2004 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) GATES IN ENCLOSURE TO OPEN AWAY FROM POOL AREA 2) FILL IN AREA SOLIDLY SOUTH WEST CORNER OF BARRIER UNDER METAL FENCE (APPROX 16" X 16" AREA
04/20/2004 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection 0999*/ 1) NEED AN ACCURATE LOAD CALC OF SERVICE EQUIPMENT AND POWER DEMAND 2) FILL IN UNDER BARRIER AWT SOUTH CORNER LARGE HOLE APPROX 16" X 16" 3) TREE NEXT DOOR NEEDS TO BE ADDRESSED, GIVES ENTRY TO POOL OVER THE 4' WALL, SOUTH SIDE 4) SPA IS NOT SHOWN ON PLOT PLAN 5) PLAN SHOWS A 70 AMP PANEL YOU HAVE 100=LOAD CALC SERVICE 6) PRE-GUNITE INSP. DOESN'T APPROVE ELECTRIC UNDERGROUND FROM SERVICE TO SUB-PANEL 7) TREES AND HOLE IN BLOCK WALL, NORTH SIDE, FENCE IS NOT HIGH ENOUGH CHAIN LINK AT REAR AFFORDS A HAND HOLD 8) ROMEX IN BOXES INSIDE ENCLOSURE, NOT ON PLAN 9) INSTALL A REBAR STAKE AT LIGHT J-BOX AND BOND THE J-BOX
04/15/2004 POOL/SPA FINAL/BARRIER Denied 1) NO ANSWER AT DOOR. DOGS LOOSE 2) PLEASE CALL AGAIN AND LOCK UP DOGS