Case: T03VL00797

Parcel: 137334530


Addresses:

1741 W SAUVIGNON DR

Inspection Status: Violation

Inspection History: INITIAL CODE VIOLATION

Date Description Inspector Results Comments
09/22/2003 INITIAL CODE VIOLATION Violation VACANT & BOARDED. NO PERMIT AT THIS TIME.F/U 10/22/2003
09/13/2003 INITIAL CODE VIOLATION Violation EMERGENCY CALLOUT - FIRE AT RESIDENCE
VEHICLE RAN INTO ELECTRIC, CABLE, PHONE PEDESTAL KNOCKING ALL THREE OVER, AT 1708 W SAUVIGNON PL. THIS CAUSED A FAULT (ELECTRICAL) TO GO THRU CABLE CIRCUITS GOING INTO SEVERAL HOUES ON THIS STREET. THE FAULT ENTERING THE HOUSE AT 1741 W SAUVIGNON DR WAS SO SEVERE THAT A FIRE WAS STARTED AS THE CABLE CAME UP ON THE WEST SIDE OF HOUSE OUTDOOR BELOW ELECTRIC SERVICE, A FIRE STARTED WHICH BURNED THE ELECTRIC SERVICE, CABLE AND PHONE SERVICE, INCLUDING THE SIDE OF THE HOUSE. (SEE DAMAGE REPORT). ELECTRIC AND GAS UTILITIES DISCONNECTED, ONE 4X4 WINDOW BOARDED. F/U 09/19/03
09/13/2003 INITIAL CODE VIOLATION Violation DAMAGE REPORT: N&O SIGNED
LOCATION: ELECTRICAL SERVICE LOATION, WEST SIDE. ALSO CABLE AND PHONE SERVICE LOCATIONS SIDE OF ELECTRICAL AREA 8'X10' CENTERED AT ELECTRICAL SERVICE - BURNED EXTERIOR PANELING, SINGED ROOF FACIAL, DAMAGED SHEET ROCK IN BEDR ROOM NEXT TO ELECTRICAL SERVICE WINDOW 4'X4' FIRE DAMAGED.
ELECTRICAL: ENTIRE SEVICE WILL NEED TO BE REPLACED, CIRCUIT TO AC BURNED, WIRING INSIDE WALL BEHIND SERVICE WILL NEED TO BE INSPECTED PRIOR TO RE-ENERGIZING;
PLUMBING: NONE
MECHANICAL: AC APPERS TO HAVE BEEN DAMAGED BY HEAT IN AND OUT LINES SINGED, FINS ON AC MELTED;
SUMMARY: A PERMIT FOR AN ELECTRICAL SERVICE, AC UNIT, REPAIR ON EXTERIOR AND INTERIOR OF HOUSE TO BE OBTAINED FOR REPAIR.