Case: T03VL00503

Parcel: 13113219B

Inspection Status: Correction Required

Inspection History: INITIAL CODE VIOLATION

Case Number - T03VL00503

Inspection Description - INITIAL CODE VIOLATION

Inspection Status - Correction Required

Date Description Inspector Results Comments
05/14/2003 INITIAL CODE VIOLATION Correction Required VERIFIED ALL ELECTRICAL & GAS METER DISCONNECTED AFTER TFD ALLOWED ENTRY REVIEWED DAMAGED ALL 3 UNITS ON TOP FLOOR NORTH SIDE AND 3 BOTTOM UNITS HEAVILY DAMAGED BY FIRE AND WATER.
AFTER REVIEW WITH CHIEF WILSON ENTIRE BUILDING UNITS 1-15 AND UTILITIES TO BE CONDEMED. WILL NOTIFY FOR FENCING CONTRACTOR TO FENCE OF BUILDING.
PERMITS FOR REMODEL LL TRADES REQUIRED FOR TOP NORTH 3 UNITS, BOTTOM 3 NORTH UNITS, ROOF REPAIR NORTH 1/3 AND RECONNECTS FOR UNDAMAGED UNITS ONE ELECTRICAL &PLUMBING PERMITS OBTAINED.
CAUSE OF DAMAGED: FIRE
LOCATION OF DAMAGE: NORTH SECTION OF BUILDING TOP 3 APTS AND BOTTOM 3 APTS ON 2 STORY BLDG.
BUILDING: 6 APTS MENTIONED ABOVE HEAVILY FIRE AND WATER DAMAGED ROOF AREA OVER MENTIONED UNITS TO BE REPAIRED OR REDONE.
ELECTRICAL: ALL WIRING IN ABOVE MENTION UNITS DAMAGED
PLUMBING: WALL IN UNITS AFFECTED STILL STANDING COULD NOT VERIFY.
MECHANICAL: UNITS IN 6 MENTIONED APTS DAMAGED TO BE REPLACED.
SUMMARY: OWNER OF BUILDING TO OBTAIN SERVICES OF REGISTERED ARCHITECT TO REVIEW ALL DAMAGED AREAS PROVIDE PLANS FOR REPAIR TO DSC OBTAIN PERMITS AND INSPECTIONS PRIOR TO OCCUPANCY. ELECTRICAL & PLUMING CONTRACTOR TO REVIEW UNDAMAGED UNITS IF REPAIR REQUIRED OBTAIN PERMIT & INSPECTIONS IF REPAIR NOT REQUIRED OBTAIN RECONNECT PERMITS FOR GAS & ELECTRICAL OWNER REP RESPONSBILE TO KEEP ALL FIRE DAMAGED AREAS FENCED OFF TO SECURE AREA FROM ENTRY. FOLLOW UP 6/13/03