Case: T03VL00495

Parcel: 116124340


Addresses:

1414 W SONORA ST

Inspection Status: Approved

Inspection History: FOLLOW UP CODE VIOLATION

Date Description Inspector Results Comments
08/25/2003 FOLLOW UP CODE VIOLATION Approved PERMITS ISSUED, INSPECTIONS ARE BEING PERFORMED BY GEN INSP SECTION. CLOSE THIS CASE FOR B.W.O.P.
07/29/2003 FOLLOW UP CODE VIOLATION Correction Required ARCHITECT WORKING WITH CONTRACTOR ON PLANS. F/U 08/05/03
07/15/2003 FOLLOW UP CODE VIOLATION Violation 1) ENCLOSED THE REAR PORCH FOR A KITCHEN;
2) ENCLOSED SE FRONT PORCH FOR A BEDROOM, KITCHEN CEILING/ROOF JOINTS ARE 2"X6"S SPANNING 12'10". THESE ARE OVERSPANNEDL 12'10" IS BETWEEN WALLS; JOINTS FOR SE BEDROOM APPEAR TO BE 2"X8"S, COULD NOT ACCURATELY VERIFY (PERMITS REQUIRED)
3) A/C UNIT ON ROOF INSTALLED WOP; 50 AMP, SQUARE D BREAKER IN A SIEMENS MAIN PANEL. #8 WIRE FROM BREAKER UP TO AC DISCONNECT ON THE ROOF. THIS SYSTEM MUST E PROPERLY SIZED AND BROUGHT UP TO CODE (PERMITS REQUIRED);
4) AC DUCT WORK ON THE ROOF MUST BE PROPERLY SIZED AND INSULATED PER CODE (PERMITS RQUIRED);
5) PROVIDE ELECTRICAL AND PLUMBING DIAGRAMS FOR THE KITCHEN, AND ELECTRICAL DIAGRAM FOR THE SE BEDROOM;
6) RE-TEST THE GAS PIPING USING A PRESSURE GAUGE THAT IS CALIBRATED IN 1/10 PSI INCREMENTS;
7) A PERMIT IS REQUIRED FOR THE INSTALLATION OF THE WATER HEATER. CALL FOR INSPECTION AFTER THE PERMIT IS ISSUED.
F/U 07/29/03
07/08/2003 FOLLOW UP CODE VIOLATION Correction Required SPOT CHECKED 3 WINDOWS BY DRILLING THRU;
1) HIT METAL ON ALL THREE. LINTELS ARE METAL;
2) A/C FUSED W/60 AMP FUSES, UNIT REQUIRES 40 AMP MAX;
3) NEED MECH INSP TO VERIFY DUCTWORK ON TOP OF UNIT;
4) CONTRACTOR HAS AFFIDAVITS FROM NEIGHBORS ON BOTH SIDES STATING NO PORCHES, EXTERIOR AREAS, CARPORTS, ETC WERE ENCLOSED AFTER 07/16/02;
5) GET W/HENRY AND STEVE RE ABOVE;
6) WEST BEDROOM NORTH SIDE OF WINDOW; DUPLEX OUTLET IS SWITCHED, ALL OTHER OUTLETS OK, GFCI'S OK;
7) ALL WORK COVERED, INTERMEDIATE INSPECTIONS NOT PERFORMED;
8) WHO INSTALLED A/C UNIT?
06/26/2003 FOLLOW UP CODE VIOLATION Compliance PERMIT T03CM01809 ISSUED FOR SFR REMODEL
06/12/2003 FOLLOW UP CODE VIOLATION Violation NOV ISSUED TO PALATINE PROPERTIES FOR ENCLOSING PORCHES, INSTALLING A/C UNIT ON ROOF AND INSTALLING NEW WATER HEATER, UNIT LOCKED OTHER VIOLATIONS MAY EXIST.
05/15/2003 FOLLOW UP CODE VIOLATION Violation PERMIT IN WINDOW FOR GAS RECONNECT.
1) ENTRY DOOR 30" MAX;
2) NEW WATER HEATER ELECTRICAL;
3) REAR PORCH IS NOW KITCHEN. (PERMITS);
4) CHECK FOR PERMITS FOR A/C