Inspection History Details
Inspection Status: Approved
Inspection History: FOLLOW UP CODE VIOLATION
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/25/2003 | FOLLOW UP CODE VIOLATION | Approved | PERMITS ISSUED, INSPECTIONS ARE BEING PERFORMED BY GEN INSP SECTION. CLOSE THIS CASE FOR B.W.O.P. | |
| 07/29/2003 | FOLLOW UP CODE VIOLATION | Correction Required | ARCHITECT WORKING WITH CONTRACTOR ON PLANS. F/U 08/05/03 | |
| 07/15/2003 | FOLLOW UP CODE VIOLATION | Violation | 1) ENCLOSED THE REAR PORCH FOR A KITCHEN; 2) ENCLOSED SE FRONT PORCH FOR A BEDROOM, KITCHEN CEILING/ROOF JOINTS ARE 2"X6"S SPANNING 12'10". THESE ARE OVERSPANNEDL 12'10" IS BETWEEN WALLS; JOINTS FOR SE BEDROOM APPEAR TO BE 2"X8"S, COULD NOT ACCURATELY VERIFY (PERMITS REQUIRED) 3) A/C UNIT ON ROOF INSTALLED WOP; 50 AMP, SQUARE D BREAKER IN A SIEMENS MAIN PANEL. #8 WIRE FROM BREAKER UP TO AC DISCONNECT ON THE ROOF. THIS SYSTEM MUST E PROPERLY SIZED AND BROUGHT UP TO CODE (PERMITS REQUIRED); 4) AC DUCT WORK ON THE ROOF MUST BE PROPERLY SIZED AND INSULATED PER CODE (PERMITS RQUIRED); 5) PROVIDE ELECTRICAL AND PLUMBING DIAGRAMS FOR THE KITCHEN, AND ELECTRICAL DIAGRAM FOR THE SE BEDROOM; 6) RE-TEST THE GAS PIPING USING A PRESSURE GAUGE THAT IS CALIBRATED IN 1/10 PSI INCREMENTS; 7) A PERMIT IS REQUIRED FOR THE INSTALLATION OF THE WATER HEATER. CALL FOR INSPECTION AFTER THE PERMIT IS ISSUED. F/U 07/29/03 |
|
| 07/08/2003 | FOLLOW UP CODE VIOLATION | Correction Required | SPOT CHECKED 3 WINDOWS BY DRILLING THRU; 1) HIT METAL ON ALL THREE. LINTELS ARE METAL; 2) A/C FUSED W/60 AMP FUSES, UNIT REQUIRES 40 AMP MAX; 3) NEED MECH INSP TO VERIFY DUCTWORK ON TOP OF UNIT; 4) CONTRACTOR HAS AFFIDAVITS FROM NEIGHBORS ON BOTH SIDES STATING NO PORCHES, EXTERIOR AREAS, CARPORTS, ETC WERE ENCLOSED AFTER 07/16/02; 5) GET W/HENRY AND STEVE RE ABOVE; 6) WEST BEDROOM NORTH SIDE OF WINDOW; DUPLEX OUTLET IS SWITCHED, ALL OTHER OUTLETS OK, GFCI'S OK; 7) ALL WORK COVERED, INTERMEDIATE INSPECTIONS NOT PERFORMED; 8) WHO INSTALLED A/C UNIT? |
|
| 06/26/2003 | FOLLOW UP CODE VIOLATION | Compliance | PERMIT T03CM01809 ISSUED FOR SFR REMODEL | |
| 06/12/2003 | FOLLOW UP CODE VIOLATION | Violation | NOV ISSUED TO PALATINE PROPERTIES FOR ENCLOSING PORCHES, INSTALLING A/C UNIT ON ROOF AND INSTALLING NEW WATER HEATER, UNIT LOCKED OTHER VIOLATIONS MAY EXIST. | |
| 05/15/2003 | FOLLOW UP CODE VIOLATION | Violation | PERMIT IN WINDOW FOR GAS RECONNECT. 1) ENTRY DOOR 30" MAX; 2) NEW WATER HEATER ELECTRICAL; 3) REAR PORCH IS NOW KITCHEN. (PERMITS); 4) CHECK FOR PERMITS FOR A/C |